مقاله A new approach to scatter correction in SPECT images based on Klein_Nishina equation


در حال بارگذاری
23 اکتبر 2022
فایل ورد و پاورپوینت
2120
2 بازدید
۷۹,۷۰۰ تومان
خرید

توجه : به همراه فایل word این محصول فایل پاورپوینت (PowerPoint) و اسلاید های آن به صورت هدیه ارائه خواهد شد

 مقاله A new approach to scatter correction in SPECT images
based on Klein_Nishina equation دارای ۱۲ صفحه می باشد و دارای تنظیمات در microsoft word می باشد و آماده پرینت یا چاپ است

فایل ورد مقاله A new approach to scatter correction in SPECT images
based on Klein_Nishina equation  کاملا فرمت بندی و تنظیم شده در استاندارد دانشگاه  و مراکز دولتی می باشد.

توجه : در صورت  مشاهده  بهم ریختگی احتمالی در متون زیر ،دلیل ان کپی کردن این مطالب از داخل فایل ورد می باشد و در فایل اصلی مقاله A new approach to scatter correction in SPECT images
based on Klein_Nishina equation،به هیچ وجه بهم ریختگی وجود ندارد


بخشی از متن مقاله A new approach to scatter correction in SPECT images
based on Klein_Nishina equation :

سال انتشار : ۲۰۱۳

تعداد صفحات :۱۲

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media.
Methods: The objective of this paper is to develop and validate a scatter correction technique that use an accurate analytical model based on Klein_Nishina scatter equation and compare Klein_Nishina scatter estimation with triple energy window. In order to verify the proposed scattering model several cylindrical phantoms were simulated. The linear source in the cylindrical Phantoms was a hot rod filled with 99mTc. K factor defines as the ratio of scatter resulting from MC simulation to scatter estimated from Klein_Nishina formula. Also a SPECT/CT scan of the image quality phantom was acquired. Row data were transferred to a PC computer for scatter estimation & processing of the images using MLEM iterative algorithm in MATLAB software.
Results: The scatter and attenuation compensated images by the proposed model had better contrast than uncorrected and only attenuation corrected images. The K-factors that used in proposed model doesn’t vary with different activities & diameters of linear source and they’re just a function of depth and composition of pixels.

Conclusion: Based on Mont Carlo simulation data, the K_N formula that used in this study demonstrates better estimation of scattered photons than TEW. Proposed scattered correction algorithm will improve 52.3% in the contrast of the attenuated corrected images of image quality phantom.